Casella-cel CEL-593 Instrukcja Użytkownika Strona 16

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 15
SETTINGS
REVIEW
'A'
STOPSLM 1
LIN FAST
PREV
VALUE
NEXT
VALUE
SLM
(2nd BARGRAPH ONLY)
GS-17
RECORD TIMER OFF
1
/
3
Q=3
=
1
/
3
more
Table 2: Typical Measurement Tasks
Task Suggested Settings
Determine Noise Exposure of
Employees Working Near an
Impact Press
Use broad band ENV with 1 second period and EVT
enabled,
Measure Leq and LinPeak, Inspect period profiles,
Check events.
Measurements to Aid Selection of
Hearing Protection Suitable for the
Employees Above
Use
1
1
octave band real time SLM,
Store SPLmax spectra followed by L
eq
spectra,
Apply data to protector selection chart.
Reduce Noise Levels in Location
Adjacent to a Noise Source
Use
1
3
octave band real time SLM,
Compare stored SPL spectra from source with SPL
spectra from location,
Check for noise leaks/improvements.
Perform Annual Octave Band Noise
Survey in Factory at 102 Locations
Use
1
1
octave band real time SLM,
Store L
eq
spectra snapshots at each location.
Investigate Intermittent Industrial
Noise Disturbing a Quiet Neighbour-
hood
Use
1
3
octave band ENV with 10 minute period and EVT
enabled,
Measure L
eq
and determine Ln spectra values such as L
95
background noise, Check for events.
Police Cumulative Noise Limits Set
for a Quarry
Use broad band ENV with 60 minute period,
Measure L
eq
, SPLmax and determine Ln values such as
L
95
background noise.
Determine the Effect of Running
New Trains Through Quiet Country-
side
Use
1
3
octave band ENV with 10 minute period and EVT
enabled,
Measure L
eq
, SEL and determine Ln spectra values such
as L
95
background noise,
Check event frequency profiles,
Use data to find projected daily L
eq
from train frequency.