Casella-cel CEL-193 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Casella-cel CEL-193. Casella CEL CEL-193 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 20
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Casella USA
17 Old Nashua Rd #15
Amherst, NH 03031 USA
CEL-193
Precision Impulse
Integrating Sound Level Meter
Handbook
[email protected] Page 1 of 20 Tel: (800) 366-2966
www.casellausa.com
2 Mar 2009 Fax: (603) 672-8053
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - Precision Impulse

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA CEL-193 Precision Impulse Integrating Sound Level Meter Handbook [email protected]

Strona 2

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA The true definition of Leq is based upon the integral of the instantaneous sound pressure leve

Strona 3 - CONTENTS

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA Leq (cumulative) = 10 log x 1/T[t1 x antilog (Leq1/10) + t2 x antilog (Leq2/10)] where Leq1

Strona 4

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA made over the range 13dB(A) to 130dB(A). To fit this microphone to the instrument the CEL-B3115

Strona 5

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA 10 Use with Ancillary Instruments 10.1 Use with tape recorders Recording procedure On the soc

Strona 6

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA This signal was recorded -2dB on tape saturation so on replay it should be adjusted to be -2d8

Strona 7

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA Block diagram of CEL-193 Sound Level Meter Within the main instrument there is an input amp

Strona 8

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA The maximum storage function is also digital in order to overcome signal decay problems. The s

Strona 9

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA CEL 202 DIGITAL DISPLAY UNIT This self-contained accessory attaches to the base of the instrum

Strona 10

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA 14 Manufacturers Servicing and Warranty Agreement Each instrument has been carefully inspecte

Strona 11

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA Post Production Developments This manual cov

Strona 12

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA This page is intentionally blank [email protected] Page 2 of 20 Tel: (800

Strona 13

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA [email protected] Page 20 of 20 Tel: (800) 366-2966 www.casellausa.com 2 Mar 2009 Fax:

Strona 14

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA CONTENTS Page 1 Schedule of Parts 4 2 Preparing the Instrument for Use 4 2.1 Connect

Strona 15

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA 1 Introduction The CEL-193 is a full specification Precision Impulse Integrating Sound Level

Strona 16

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA be replaced, it must be appreciated that the meter movement employed in the instrument has. a v

Strona 17

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA In order to read the maximum value logged during the measurement sequence, the MAX position sho

Strona 18

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA however, a trigger is set when the first overload occurs which will cause the lamp to be perman

Strona 19

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA the attenuator setting and, when activated, the 30dB range expansion. The detailed measurement

Strona 20 - Lucas CEL Instruments Ltd

Casella USA 17 Old Nashua Rd #15 Amherst, NH 03031 USA 3.3 Frequency Weighting Selection This should be selected by the operator to suit the applicat

Komentarze do niniejszej Instrukcji

Brak uwag